Archive | References

Textile dye house Fezko Strakonice

For 400 m3 of waste water per day at a temperature of 35-45 ° C  designed heat exchanger SUP-2 on six floors of the two absorbers in series. Waste water preheated  the clean water inlet about more than 12 ° C. Daily savings by running  are 2 900-4 000 kWh. Type of the waste water heat exchanger: SUP […]

Continue Reading →

Lipova Spas & Wells

Designed exchanger SUP-3 with three floors of the two absorbers handles about 10.5 m3 / h oily wastewater from herbal baths. Wastewater temperature is about 38 ° C. Input clean water with 10 ° C is preheated about more than 12 ° C. Return exchanger is approximately 1 year. Type of the waste water heat exchanger: SUP […]

Continue Reading →

Small pool Children center Tabor

Type of the waste water heat exchanger: 2x SUP – mini In service since: 1.9.2006 Waste water temperature and amount: 30 oC 1,4m3/hour. 12 hours/day In the first level water is preheated + 6oC In the second level this water is heated by the heat pump

Continue Reading →

Laundry Jihlava

Type of the waste water heat exchanger: SUP – 3 In service since: 17.4.2003 Waste water temperature and amount:     45 oC 9,5m3/hour. 10 hours/day Cold clean water temperature and amount: 8 oC 9,5m3/hour. Guaranteed savings per day (10 hours): 2 100 kWh.

Continue Reading →

Textile dye house Holzbecher Zlíč

Type of the waste water heat exchanger: SUP – 1 In service since: 14.12.2002 Waste water temperature and amount:      50 oC 5m3/hour. 24 hours/day Cold clean water temperature and amount: 10 oC 5m3/hour. Guaranteed savings per day: 3,700 kWh.

Continue Reading →